Liner Servo Amplifier - AMLS Series

AMLS
YUKEN

Linear Servo Amplifier

How to order

AMLS-A-D48-A1-10
Model Applicable Valve Type Supply Voltage Input Signal/Spool
Travel Monitoring
Design Number
AMLS:
Linear Servo
Amplier
A: LSVG-03-4/10/20/40
B: LSVG-03-60
C: LSVHG-06-900 &
LSVHG-10-1500
C2: LSVHG-04-750
LSVHG-06-1300
D48: 48 VCD
D24: 24 VCD
A1: Voltage Signal 10
V B1: Current Signal 4 to 20mA
C1: Current Signal 10mA
10

Specification

Description\Model NumbersAMLS-*-D48-*-10AMLS-*-D24-*-10
Power Supply DC 48 V 2.4 V (200 VA or more) DC 24 V 1.2 V (75 VA or more)
Rate Output Current Continuos 2 A (4 A Peak) Continuos 2 A (3 A Peak)
Input / Output Signal AMLS-*-D48/D24-A1- AMLS-*-D48/D24-B1- AMLS-*-D48/D24-C1- Output Signal = Spool Travel Monitoring Voltage Signal 10 V (Ri = 100 kΩ, RL ≥ 10 kΩ ) Current Signal 4 - 20 mA (Ri = 200Ω, RL≥100 - 500 kΩ ) Current Signal 10 mA (Ri = 200Ω, RL ≥100 - 500 kΩ )
Control Input / Output Signal a) Servo "NO" Input/Alarm Reset Input: Photo coupler Input Voltage: + 15 VDC to + 28 V, Input Impedance: 2.2Ωk b) Over current output (Curr.AL.)/Deviation Alarm Output(CRTL.AL.): Photo coupler Output Voltage: Max.50 VDC, Current: Max. 30 mA
Ambient Temperature 0 - 50°C (32 - 122 °F)
Ambient Humidity 20 - 90 %RH (No Condensation)
Mass 1.8 kg (4.0 lbs.)

Servo Valves - LSVHG Series

LSVG-Series
YUKEN

Symbol : Servo Valoves - Model. LSVHG Series

LSVHG

Servo Valves

OBE (ON-BOARD ELECTRONICS)TYPE LINEAR SERVO VALVES (เซอร์โววาล์วแบบมีการ์ดแอมพลิไฟล์ในตัว)

How to order

F-LSVHG-06EH-900-2P-ET-A1-20
Special
Seals
Series
Number
Valve
Size
Amp.Type Rated Flow
@P = 7MPa
@P = 1020(PSI)
Spool Type PilotConnection Drian
Connection
InputSignal/
Spool
Travel
Monitoring
Connector
Type

Design
Number

F: Special
Seals for
Phosphate
Ester Type
Fluid (Omit if not Required)

LSVHG: Two
Stage
Type Linear
Serv
oValves
03 EH: OBH Type (การ์ดแยก) 230: 230 L/min
(60.8 U.S. GPM)
2L: 2 %
Overlap
spool-type1
(Linear Flow Gian )
2: 10%
Overlap
spool-type1
40: Open
Centre
A, B & T
spool-type2
2P: ZeroLap
spool-type1
(Dual FlowGian)
None:Internal Pilot
E:External Pilot
None:Internal Drain
E:External Drain
A: VoltageSignal 10 V
B: Current Signal 4 to 20 mA
C: Current Signal 10 mA
1: 6
+ PE Pole
2: 11
+ PE Pole
20
04 270: 270 L/min
(70.3 U.S. GPM)
06 750: 750 L/min
(198 U.S. GPM)
20
900: 900 L/min
(238 U.S. GPM)
1300: 1300 L/min
(343 U.S. GPM)
20